Ir-192 Exposure Time Calculation

Ir-192 Exposure Time Calculation

Ir-192 Exposure Time Calculation

Ir-192 Exposure Time Calculation
(toc)

Basic for Ir-192 Exposure Time Calculation

For calculate the exposure time, the fallowing steps should be imported
1. Calculate the present source activity in curies(ci) from the decay charts.
2. Find thickness (cm) of the object.
3. Find HVT (cm) of object material, foe the given source by HVT Table.
4. Write RHM value (0.48 for Iridium-192)
5. Find film factor (FF in Roentgen) from Given Table.

Film Factor Table of Ir-192 (R)

SourceNDT-65NDT-70Fast FilmAgfa D-7Agfa D-4Agfa D-5Agfa D-2
Iridium-1921.41.00.91.24.05.39.5

Substitute all these values in the following formula

     Exposure Time Calculation Formula is:

Exposure Time Calculation Formula is:

\[ ET = \frac{FF * 2^{(T/HVT)} * SFD^2 * 60}{Ci * RHM * 100^2} \]
where: ET = Exposure Time in Minutes
            FF = Film Factor please put your using film FF correctly (D-7 is 1.4)
            T = Object Thickness
            HVT = HVT (cm) of object material (Steel is 12.5cm)
            SFD = Source to Film Distance in cm
            Ci = Current Activity of Source in curies (Ci)
            RHM = Source RHM value in Roentgen (.48)

It may be noted that this formula is not very accurate for higher thickness, particularly when using cobalt-60 source.
 
Calculate given formula below to calculate Ir-192 Exposure Time Calculation.

NDT Check

For Ir-192 Expose Time Calculation for Steel Object

Film Factor . . . . . . . . . :

Steel Thickness (mm):

Current Activity . . . . . :

SFD (cm) . . . . . . . . . . . :

The Result in Minutes is :

#buttons=(Ok, Go it!) #days=(20)

Our website uses cookies to enhance your experience. Check Now
Ok, Go it!